Server Technology
Server Tech CWG-16H2A454
The Server Technology Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS and POPS technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched POPS "Master" PDU can be connected to a Switched POPS "Link" PDU to extend the network access to the redundant or secondary power feed.
Features & Benefits
- (16) C13 outlets
- Network Monitoring
- Linkable Expansion
- Temperature/Humidity Monitoring
- Per-Inlet Power Sensing
- Per-Outlet Power Sensing
- Branch Circut Protection
- Outlet Control
- High Retention Locking Outlets
- Color Identification
- Cisco Energywise Compliant
Product Specifications
Input Power Capacity (kW) | 3.3 |
Input Plug Type | IEC C20 200-240V Inlet |
Input Current (A) | 20 |
Input Current Rated (A) | 16 |
Input Nominal Voltage (V) | 208 |
Input Phase | 1-Phase (L-L) |
Input Cord Location | Horizontal |
Outlet Form Factor | Conventional |
Total Outlets | 16 |
IEC C13 Count | 16 |
Product Family Specifications
Branch Monitoring | Sense |
Branch Overcurrent Protection | 5 kAIC |
Branch Overcurrent Protection Type | Circuit Breaker |
Dual Input | No |
High Retention Outlets | Yes |
Input Current Display | Auto-Orient |
Input Monitoring | PIPS |
Locking Outlets | Yes |
Max Operating Temp | 50°;C |
Fast Movers | No |
Mounting | 2U Horizontal |
Outlet Monitoring | POPS |
PDU Platform | CDU1 |
Power Pivot Input | No |
Product Height | 3.5 in (89 mm) |
Product Depth | 7.1 in (181 mm) |
Product Width | 17.2 in (437 mm) |
The Server Technology Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS and POPS technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched POPS "Master" PDU can be connected to a Switched POPS "Link" PDU to extend the network access to the redundant or secondary power feed.
Features & Benefits
- (16) C13 outlets
- Network Monitoring
- Linkable Expansion
- Temperature/Humidity Monitoring
- Per-Inlet Power Sensing
- Per-Outlet Power Sensing
- Branch Circut Protection
- Outlet Control
- High Retention Locking Outlets
- Color Identification
- Cisco Energywise Compliant
Product Specifications
Input Power Capacity (kW) | 3.3 |
Input Plug Type | IEC C20 200-240V Inlet |
Input Current (A) | 20 |
Input Current Rated (A) | 16 |
Input Nominal Voltage (V) | 208 |
Input Phase | 1-Phase (L-L) |
Input Cord Location | Horizontal |
Outlet Form Factor | Conventional |
Total Outlets | 16 |
IEC C13 Count | 16 |
Product Family Specifications
Branch Monitoring | Sense |
Branch Overcurrent Protection | 5 kAIC |
Branch Overcurrent Protection Type | Circuit Breaker |
Dual Input | No |
High Retention Outlets | Yes |
Input Current Display | Auto-Orient |
Input Monitoring | PIPS |
Locking Outlets | Yes |
Max Operating Temp | 50°;C |
Fast Movers | No |
Mounting | 2U Horizontal |
Outlet Monitoring | POPS |
PDU Platform | CDU1 |
Power Pivot Input | No |
Product Height | 3.5 in (89 mm) |
Product Depth | 7.1 in (181 mm) |
Product Width | 17.2 in (437 mm) |