Skip to main content

Explore products on our other websites for all of your datacenter needs

Zoom the image with the mouse

ZONIT uATS1-LV-YC13-515-4

No reviews yet
Product Code: uATS1-LV-YC13-515-4
Minimum Purchase: 10 units
Input Voltage: 120V
Power Input: NEMA 5-15
Power Output: C13

ZONIT uATS1-LV-YC13-515-4

  • Input Voltage:120V, 50/60 Hz (1-3 Phase)
  • Max. Amperage:12A
  • Power Input:(2) NEMA 5-15, 4ft Cords
  • Power Output:(1) C13, 1ft Cord
  • Warranty:3 years
  • Approvals:UL, CE

The Zonit Micro Automatic Transfer Switch (uATS) is the world’s smallest ATS and solves the problem of supplying A+B redundant power to single power supply devices. The Micro uATS draws power from A and monitors power quality. The uATS will automatically switch to secondary B power when A fails or becomes degraded in quality. The µATS will switch back to A when it returns and is of sufficient quality. The Micro uATS will transfer regardless of phase angle between A and B.

ZONIT Micro uATS Features & Benefits

  • Eliminates the need for expensive dual-power suppliesin devices, simply use Micro ATS on a individual device basis for cost effective N+1 redundant deployment. Micro ATS can be moved over to a new device when the old one fails or is replaced.
  • The uATS is not phase dependentand does not need to be phase aligned - automatic universal power for 1-3 phase.
  • In the case of a power failure, only loose access to one to three devices instead of a full array of devices like with a typical ATS.
  • MTBF (Mean time between failures)is an astounding 22 Years.
  • Save valuable rack spaceby getting non-rackmounted ATS's.
  • Ultra fast input power switching:
    A to B: 12-14 ms
    B to A: 6-8 ms
  • 99.9% Efficient Power Distributionsaves 3-15% of annual data center power costs
  • Increase UPS Efficiency by 3-5%:Saves 3-5% of UPS power conversion losses
  • uATS is the only 1-to-1 automatic transfer switchseries on the market.
  • Works with Cisco and other network switches
  • Also great for smaller applicationslike home, small office, food trucks, etc.
  • Each unit is testedin manufacturing before shipment.
  • Used by over 30% of the Fortune 100

Download IconDownload the

ZONIT uATS LV Data Sheet (PDF)
ZONIT uATS LV Manual (PDF)
ZONIT uATS Advantages (PDF)

Why use the uATS?

The µATS allows single power supply devices in the data center to be connected to redundant A-B power sources. This eliminates one of the primary causes of downtime, human error. Much downtime is caused by people plugging in one too many devices to a branch circuit, causing its circuit breaker to trip.

The Zonit µATS is very useful to increase the service level availabilty of common single-power devices such as network distribution switches, firewalls, and other equipment that may be in a mission-critical service path, sometimes unknowingly.

The µATS enables much easier maintenance of redundant power systems, since one source can be taken off-line if all single power supply devices are fed via µATS units.

Distribution closets with single power supply network switches especially benefit from the Zonit µATS, because it enables a UPS unit in that closet to be taken off-line for battery testing and maintenance during regular business hours without network service downtime.

Re-Location Flexibilityallows easy "hot moves" (hot pluggable) to relocate powered-up equipment within the rack or between racks Ideal for doing deployments that are temporary or will be moved at a later date

99.9% Efficient Power Distribution
The Zonit Micro ATS (µATS) enables 99%+ efficient power distribution methods in the data center. It allows data center devices to be preferentially connected to filtered utility power on the A side and an Uninterruptible Power Supply (UPS) on the B side, which is only used when A is down. Eliminating UPS power conversion losses saves 3-15% of data center power usage compared to redundant UPS designs, which can save millions of dollars in energy costs. The µATS is 99.75% efficient, using only 125mA in normal operation. This maximizes data center Power Utilization Efficiency (PUE).

Micro ATS Power Efficiency Graph

Modern computer power supplies are almost all auto-ranging (accept 110-240V input) and all switched (Draw on the Alternating Current [AC] input power for just a short period of time and then convert this energy to Direct Current [DC], then repeat). Power supplies of this type are more resistant to power quality problems, because they only need to “drink one gulp at a time, not continuously. If the input AC power voltage range is controlled within a known range, they will function very reliably. They do not require perfect input AC waveforms to work well. All that is necessary is that they receive sufficient energy in each “gulp and that the input power is within the limits of their voltage range tolerance. This makes it possible to use a data center power distribution system that is much more efficient than a fully UPS supplied power system at a very reasonable capital expense.

ZONIT uATS1-LV-YC13-515 Specifications

Physical
Length 0.75 in. (19 mm.)
Width 1.6 in. (40.9 mm.)
Depth 4.25 in. (109 mm.)
Weight 0.9 lbs. (0.4 kg.)
Electrical
Rated Input Voltage 120V, 50/60 Hz
Rated Maximum Amperage 12A
Power Input (2) NEMA 5-15, 4ft Cords
Power Output (1) C13, 1ft Cord
Internal Overload Protection Virtual Circuit Breaker set at rated amperage with reset switch
Transfer Time A-B: 12-14ms
B-A: 6-8ms
Max. Power Consumption @ 120V on A: 5 ma
@ 120V on B: 13 ma
Environmental
Elevation – Operating 0 to 10,000 ft (0 to 3000m)
Elevation – Storage 0 to 50,000 ft (0 to 15000m)
Temperature – Operating 23 to 104°F (-5 to 40°C)
Temperature – Storage -13 to 149°F (-25 to 65°C)
Operating Humidity 0 to 95% Non-condensing
Approvals UL/cUL File E340237, CE
  • Norton Secured
  • TRUSTe Verified
  • Accredited Business
 

ZONIT uATS1-LV-YC13-515-4

  • Input Voltage:120V, 50/60 Hz (1-3 Phase)
  • Max. Amperage:12A
  • Power Input:(2) NEMA 5-15, 4ft Cords
  • Power Output:(1) C13, 1ft Cord
  • Warranty:3 years
  • Approvals:UL, CE

The Zonit Micro Automatic Transfer Switch (uATS) is the world’s smallest ATS and solves the problem of supplying A+B redundant power to single power supply devices. The Micro uATS draws power from A and monitors power quality. The uATS will automatically switch to secondary B power when A fails or becomes degraded in quality. The µATS will switch back to A when it returns and is of sufficient quality. The Micro uATS will transfer regardless of phase angle between A and B.

ZONIT Micro uATS Features & Benefits

  • Eliminates the need for expensive dual-power suppliesin devices, simply use Micro ATS on a individual device basis for cost effective N+1 redundant deployment. Micro ATS can be moved over to a new device when the old one fails or is replaced.
  • The uATS is not phase dependentand does not need to be phase aligned - automatic universal power for 1-3 phase.
  • In the case of a power failure, only loose access to one to three devices instead of a full array of devices like with a typical ATS.
  • MTBF (Mean time between failures)is an astounding 22 Years.
  • Save valuable rack spaceby getting non-rackmounted ATS's.
  • Ultra fast input power switching:
    A to B: 12-14 ms
    B to A: 6-8 ms
  • 99.9% Efficient Power Distributionsaves 3-15% of annual data center power costs
  • Increase UPS Efficiency by 3-5%:Saves 3-5% of UPS power conversion losses
  • uATS is the only 1-to-1 automatic transfer switchseries on the market.
  • Works with Cisco and other network switches
  • Also great for smaller applicationslike home, small office, food trucks, etc.
  • Each unit is testedin manufacturing before shipment.
  • Used by over 30% of the Fortune 100

Download IconDownload the

ZONIT uATS LV Data Sheet (PDF)
ZONIT uATS LV Manual (PDF)
ZONIT uATS Advantages (PDF)

Why use the uATS?

The µATS allows single power supply devices in the data center to be connected to redundant A-B power sources. This eliminates one of the primary causes of downtime, human error. Much downtime is caused by people plugging in one too many devices to a branch circuit, causing its circuit breaker to trip.

The Zonit µATS is very useful to increase the service level availabilty of common single-power devices such as network distribution switches, firewalls, and other equipment that may be in a mission-critical service path, sometimes unknowingly.

The µATS enables much easier maintenance of redundant power systems, since one source can be taken off-line if all single power supply devices are fed via µATS units.

Distribution closets with single power supply network switches especially benefit from the Zonit µATS, because it enables a UPS unit in that closet to be taken off-line for battery testing and maintenance during regular business hours without network service downtime.

Re-Location Flexibilityallows easy "hot moves" (hot pluggable) to relocate powered-up equipment within the rack or between racks Ideal for doing deployments that are temporary or will be moved at a later date

99.9% Efficient Power Distribution
The Zonit Micro ATS (µATS) enables 99%+ efficient power distribution methods in the data center. It allows data center devices to be preferentially connected to filtered utility power on the A side and an Uninterruptible Power Supply (UPS) on the B side, which is only used when A is down. Eliminating UPS power conversion losses saves 3-15% of data center power usage compared to redundant UPS designs, which can save millions of dollars in energy costs. The µATS is 99.75% efficient, using only 125mA in normal operation. This maximizes data center Power Utilization Efficiency (PUE).

Micro ATS Power Efficiency Graph

Modern computer power supplies are almost all auto-ranging (accept 110-240V input) and all switched (Draw on the Alternating Current [AC] input power for just a short period of time and then convert this energy to Direct Current [DC], then repeat). Power supplies of this type are more resistant to power quality problems, because they only need to “drink one gulp at a time, not continuously. If the input AC power voltage range is controlled within a known range, they will function very reliably. They do not require perfect input AC waveforms to work well. All that is necessary is that they receive sufficient energy in each “gulp and that the input power is within the limits of their voltage range tolerance. This makes it possible to use a data center power distribution system that is much more efficient than a fully UPS supplied power system at a very reasonable capital expense.

ZONIT uATS1-LV-YC13-515 Specifications

Physical
Length 0.75 in. (19 mm.)
Width 1.6 in. (40.9 mm.)
Depth 4.25 in. (109 mm.)
Weight 0.9 lbs. (0.4 kg.)
Electrical
Rated Input Voltage 120V, 50/60 Hz
Rated Maximum Amperage 12A
Power Input (2) NEMA 5-15, 4ft Cords
Power Output (1) C13, 1ft Cord
Internal Overload Protection Virtual Circuit Breaker set at rated amperage with reset switch
Transfer Time A-B: 12-14ms
B-A: 6-8ms
Max. Power Consumption @ 120V on A: 5 ma
@ 120V on B: 13 ma
Environmental
Elevation – Operating 0 to 10,000 ft (0 to 3000m)
Elevation – Storage 0 to 50,000 ft (0 to 15000m)
Temperature – Operating 23 to 104°F (-5 to 40°C)
Temperature – Storage -13 to 149°F (-25 to 65°C)
Operating Humidity 0 to 95% Non-condensing
Approvals UL/cUL File E340237, CE
 
Please note the ZONIT uATS1-LV-YC13-515-4 is a custom product requiring a minimum order quantity of 10 units. Orders are non-cancellable and non-returnable. To discuss this further, please contact your Server Racks Online sales representative.
 