Great Lakes ENSAB19

No reviews yet
Product Code: ensab-19
Weight: 16.00 LBS

ENSAB19

Cisco Baffle Kit Application

Based on your switch/equipment, choose the appropriate EN enclosure or ES enclosure. Take into consideration your cable management, cooling, and power needs; each enclosure addresses these needs in different ways. Baffle Kit part numbers are specific to EN or ES Enclosures.

The Baffle Kit Matrix below shows which kits accommodate various Cisco switches. Other brands of side-to-side airflow equipment can also be mounted. To determine the correct enclosure and baffle kit, compare physical equipment dimensions to what is listed.

 Recommended
Great Lakes Enclosures
Great Lakes
Baffle Kit
Part No.
CISCO
Equipment
Dimensions
CISCO Recommended Clearances
 EN Series EnclosureES Series
Enclosure
EN Baffle KitES Baffle KitRMUDepthDistance from
equipment to wall (i.e. enclosure side panel, or side of baffle kit)
7000 Series       
7018140"W x 48"DN/AENSAB25N/A2533.111
7010232/40"W x 48"D30"W x 48"DN/AN/A2133.1N/A
700940"W x 48"D N/AENSAB14AN/A1424.1011
7004340"W x 48"D N/AENSAB7AN/A72411
9500 Series       
951332"W x 42/48"D30"W x 42/48"DENSAB14DESSAB14D14286
950932"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141418.402.50
6800 Series       
6807-XL32"W x 42/48"D30"W x 42/48"DENSAB10D18ESSAB10D181018.106
6880-X532"W x 42/48"D30"W x 42/48"DENSAB5D23ESSAB5D235236
6500 Series
6513(-E)32"W x 42/48"D30"W x 42/48"DENSAB19ESSAB191918.106
6509 (-E)32"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141418.106
6506 (-E)32"W x 42/48"D 30"W x 42/48"DENSAB11ESSAB111118.106
4500 Series       
4510R32"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141412.506
450632"W x 42/48"D30"W x 42/48"DENSAB10D18ESSAB10D181012.506
1 Four post mounting is required with a rail placement of 24"
2 The 7010 has front to rear airflow; no left or right side clearance is requried; when installed in a cabinet, 5" rear clearance is required
3 The 7004 requires 11" clearance on the right (instake) side only; exhaust exits from the rear, no rear clearance required
NOTE: It is important to read and undersand CISCO installation guides that are associated with each switch
  • Norton Secured
  • TRUSTe Verified
  • Accredited Business
Great Lakes ENSAB19

Great Lakes

Great Lakes ENSAB19

 

ENSAB19

Cisco Baffle Kit Application

Based on your switch/equipment, choose the appropriate EN enclosure or ES enclosure. Take into consideration your cable management, cooling, and power needs; each enclosure addresses these needs in different ways. Baffle Kit part numbers are specific to EN or ES Enclosures.

The Baffle Kit Matrix below shows which kits accommodate various Cisco switches. Other brands of side-to-side airflow equipment can also be mounted. To determine the correct enclosure and baffle kit, compare physical equipment dimensions to what is listed.

 Recommended
Great Lakes Enclosures
Great Lakes
Baffle Kit
Part No.
CISCO
Equipment
Dimensions
CISCO Recommended Clearances
 EN Series EnclosureES Series
Enclosure
EN Baffle KitES Baffle KitRMUDepthDistance from
equipment to wall (i.e. enclosure side panel, or side of baffle kit)
7000 Series       
7018140"W x 48"DN/AENSAB25N/A2533.111
7010232/40"W x 48"D30"W x 48"DN/AN/A2133.1N/A
700940"W x 48"D N/AENSAB14AN/A1424.1011
7004340"W x 48"D N/AENSAB7AN/A72411
9500 Series       
951332"W x 42/48"D30"W x 42/48"DENSAB14DESSAB14D14286
950932"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141418.402.50
6800 Series       
6807-XL32"W x 42/48"D30"W x 42/48"DENSAB10D18ESSAB10D181018.106
6880-X532"W x 42/48"D30"W x 42/48"DENSAB5D23ESSAB5D235236
6500 Series
6513(-E)32"W x 42/48"D30"W x 42/48"DENSAB19ESSAB191918.106
6509 (-E)32"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141418.106
6506 (-E)32"W x 42/48"D 30"W x 42/48"DENSAB11ESSAB111118.106
4500 Series       
4510R32"W x 42/48"D30"W x 42/48"DENSAB14ESSAB141412.506
450632"W x 42/48"D30"W x 42/48"DENSAB10D18ESSAB10D181012.506
1 Four post mounting is required with a rail placement of 24"
2 The 7010 has front to rear airflow; no left or right side clearance is requried; when installed in a cabinet, 5" rear clearance is required
3 The 7004 requires 11" clearance on the right (instake) side only; exhaust exits from the rear, no rear clearance required
NOTE: It is important to read and undersand CISCO installation guides that are associated with each switch
 