The ENVIROMUX Micro Environment Monitoring System monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via external USB 3G modem).

The system functions independently or as an IP-connected remote sensor for the ENVIROMUX-2D/5D/16D. The ENVIROMUX-MICRO-TRHP features an integrated temperature/humidity sensor, two RJ45 sensor ports for external temperature/humidity sensors, two dry contact inputs and built-in Power over Ethernet (PoE).

Formerly the NTI ENVIROMUX-MICRO-TRHP.

 

  • ENVIROMUX-MICRO-TRHP
    • 1 integrated temperature/humidity combination sensor
    • 2 RJ45 ports for external temperature/humidity sensors
    • 2 digital inputs sensitive to contact closure
    • Built-in Power over Ethernet and dual DC power provides triple redundancy.
  • Sensors are hot pluggable.
  • Monitor (ping) up to 4 IP network devices – alerts are sent if devices are not responding.
  • Create multiple alerts for any installed sensor.
  • Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert.
  • Alerts are posted in message log, which is accessible through Web user interface.
  • Automatically configures network settings received from a connected DHCP server.
  • Supports 4 IP network video cameras for live view of any facility.
  • Integrates with various Open Source SNMP monitoring packages -Nagios and MRTG.
  • USB port for connecting USB modem.
  • Security: HTTPS, SSLv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.

RJ45 Sensor Ports Two RJ45 modular jacks for connecting temperature sensors or combined temperature/humidity sensors.
Dry Contact Closures Two screw terminal pairs for connecting dry contact devices and the liquid detection sensor.
USB Port One female Micro USB connector for connecting a USB Modem.
Ethernet Port One female RJ45 connector.
  10/100 Base-T Ethernet interface.
Protocols HTTP/HTTPS, SNMP V1/V2c, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSLv3, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour.
  Compatible with any SNMP management software.
  Operates and configures via HTTP/HTTPS web page.
  An IP address can be assigned to the ENVIROMUX-MICRO automatically by a DHCP server.
  Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem).
Integrated Temperature/Humidity Sensor Temp: Applications from -4 to 167°F (-20 to 75°C).
  Accuracy: ±0.72°F at -14 to 167°F (±0.4°C at -10 to 75°C).
±0.9°F at -4 to 23°F (±0.5°C at -20 to 5°C).
Dimensions WxDxH in: 4x3.44x1.37 (102x87x35 mm).
  Includes mounting holes to match rack hole spacing.
Power Built-in Power over Ethernet and dual DC power provides triple redundancy.
  110 to 240 VAC at 50 or 60 Hz via AC adapter.
  Power consumption: 4W max.
Environmental Operating & Storage Temperature: -4 to 167°F (-20 to 75°C).
  Operating & Storage Relative Humidity: 0 to 99% non-condensing RH.
Regulatory Approvals CE, RoHS
Warranty Two Years
  • Norton Secured
  • TRUSTe Verified
  • Accredited Business
NTI E-MICRO-TRHP

NTI

NTI E-MICRO-TRHP

$315.00
$289.66
(You save $25.34 )
 

The ENVIROMUX Micro Environment Monitoring System monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via external USB 3G modem).

The system functions independently or as an IP-connected remote sensor for the ENVIROMUX-2D/5D/16D. The ENVIROMUX-MICRO-TRHP features an integrated temperature/humidity sensor, two RJ45 sensor ports for external temperature/humidity sensors, two dry contact inputs and built-in Power over Ethernet (PoE).

Formerly the NTI ENVIROMUX-MICRO-TRHP.

 

  • ENVIROMUX-MICRO-TRHP
    • 1 integrated temperature/humidity combination sensor
    • 2 RJ45 ports for external temperature/humidity sensors
    • 2 digital inputs sensitive to contact closure
    • Built-in Power over Ethernet and dual DC power provides triple redundancy.
  • Sensors are hot pluggable.
  • Monitor (ping) up to 4 IP network devices – alerts are sent if devices are not responding.
  • Create multiple alerts for any installed sensor.
  • Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert.
  • Alerts are posted in message log, which is accessible through Web user interface.
  • Automatically configures network settings received from a connected DHCP server.
  • Supports 4 IP network video cameras for live view of any facility.
  • Integrates with various Open Source SNMP monitoring packages -Nagios and MRTG.
  • USB port for connecting USB modem.
  • Security: HTTPS, SSLv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.

RJ45 Sensor Ports Two RJ45 modular jacks for connecting temperature sensors or combined temperature/humidity sensors.
Dry Contact Closures Two screw terminal pairs for connecting dry contact devices and the liquid detection sensor.
USB Port One female Micro USB connector for connecting a USB Modem.
Ethernet Port One female RJ45 connector.
  10/100 Base-T Ethernet interface.
Protocols HTTP/HTTPS, SNMP V1/V2c, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSLv3, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour.
  Compatible with any SNMP management software.
  Operates and configures via HTTP/HTTPS web page.
  An IP address can be assigned to the ENVIROMUX-MICRO automatically by a DHCP server.
  Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem).
Integrated Temperature/Humidity Sensor Temp: Applications from -4 to 167°F (-20 to 75°C).
  Accuracy: ±0.72°F at -14 to 167°F (±0.4°C at -10 to 75°C).
±0.9°F at -4 to 23°F (±0.5°C at -20 to 5°C).
Dimensions WxDxH in: 4x3.44x1.37 (102x87x35 mm).
  Includes mounting holes to match rack hole spacing.
Power Built-in Power over Ethernet and dual DC power provides triple redundancy.
  110 to 240 VAC at 50 or 60 Hz via AC adapter.
  Power consumption: 4W max.
Environmental Operating & Storage Temperature: -4 to 167°F (-20 to 75°C).
  Operating & Storage Relative Humidity: 0 to 99% non-condensing RH.
Regulatory Approvals CE, RoHS
Warranty Two Years
 

Customer Reviews